LABORATORY OPERATIONS · PARTNER INTEGRATION
What is external laboratory partner api?
SmartCarePlus includes a versioned laboratory integration API for approved external partners. The reviewed contract includes credential verification, test catalog listing and detail, order creation and retrieval by platform or external ID, cancellation, report retrieval and download, and recollection acknowledgement and submission.
Facility administrators can create and manage integration keys with partner type, permissions, rate limits, expiry, and optional webhook configuration.
The existence of these routes does not by itself establish a public self-serve developer program or guarantee that every endpoint is enabled for every facility.
Key scope, partner onboarding, webhook delivery and signature verification, retry behavior, API terms, test environment, version policy, rate limits, and support commitments need explicit approval before being presented as a generally available API product.
Partners should also agree how they store the external order identifier, handle repeated requests after a timeout, interpret cancellation responses, and respond when a report is not yet ready.
Production onboarding should test expected responses as well as permission failures, expiry, revocation, and webhook verification. These details belong in approved integration documentation and commercial onboarding; they should not be inferred from a route name or a successful demonstration using one account.
THE PROBLEM
What problem does it solve?
Partners may need to discover eligible tests, submit an order, look up its status, and retrieve a report without staff manually copying each update.
Partners may need to discover eligible tests, submit an order, look up its status, and retrieve a report without staff manually copying each update. A bounded API can make that exchange more consistent while preserving facility-specific catalog and order context.
Integration access also creates a security boundary. Keys should be scoped to a facility and limited permissions, with clear expiry and revocation procedures. External IDs and retries must be managed carefully so repeated requests do not create duplicate work.
The page should be useful to technical buyers without exposing credentials or making unsupported uptime claims.
Expose a defined order lifecycle
The current route set covers test discovery, order creation and lookup, cancellation, report retrieval, and recollection actions.
Scope partner access
API-key management supports facility association, partner type, permissions, rate limit, expiry, optional webhook URL, and revoke/update actions.
Support operational callbacks
Webhook configuration is available for keys, but delivery guarantees, event catalogue, retry policy, and signature requirements must be validated for the current contract.
THE EXPERIENCE
How it works
- 1
Onboard a partner
Agree on facility scope, permitted operations, environment, API version, data purpose, and support owner before issuing credentials.
- 2
Create the minimum required access
Choose only the needed permissions and a suitable expiry and rate limit. Store the returned secret securely because it is not shown again.
- 3
Test the complete exchange
Verify test discovery, idempotent order behavior, external ID lookup, cancellation rules, report availability, recollection handoff, and any webhook signature handling.
USE CASES
Common ways teams use it
Partner test discovery
An approved integrator can query the facility’s available catalog and retrieve test details when authorized.
Order status reconciliation
A partner can retrieve an order using the known platform ID or its external identifier to reconcile the two systems.
Report and recollection exchange
A partner can retrieve report data or a download and participate in the defined recollection workflow when permissions allow.
Reconcile asynchronous work safely
An external partner should retain both the SmartCarePlus order identifier and its own external reference, then query the documented status before assuming a transition succeeded. If a request times out, the integration owner should follow the approved retry or duplicate-prevention contract rather than resubmitting blindly. A report lookup can return no available report until the laboratory completes its review and release steps. Partners need clear error handling and a human escalation contact for mismatched patient, test, or order data.
WHO IT IS FOR
Who can use this feature?
For integration developers
Use the published and approved contract, stable identifiers, scoped credentials, and documented retry/idempotency rules. Do not log tokens or patient information.
For facility owners and security teams
Approve the purpose, partner, permissions, rate limits, expiry, webhook URL, secret storage, revocation plan, and any personal-data agreement.
Availability boundary
The code contains a versioned integration surface; public API availability, sandbox access, SLA, support hours, and unrestricted partner onboarding remain release and commercial decisions.
GET STARTED
Explore external laboratory partner api
Review availability, roles, data scope, and operating steps with your SmartCarePlus product contact.
FAQs
What can an approved partner do through the API?
The reviewed routes cover test discovery, order creation and retrieval, cancellation, report retrieval/download, and recollection actions, subject to permissions.
Are API keys limited to one facility?
The key model and management controller associate keys with a facility; verify the active middleware and each endpoint’s authorization scope.
Can permissions and expiry be configured?
Key creation and update support explicit permission sets, rate limit, expiry, and optional webhook information.
Are webhooks guaranteed to be delivered?
A webhook URL and secret can be configured, but delivery retry and uptime guarantees need contract-level verification.
Is there a public sandbox and SLA?
These are not established by the route definitions alone; confirm commercial and operational readiness before advertising them.
Does a successful API response mean a report is final?